1 - What are the power requirements for my server's PSUs?

The power requirements for Lambda server power supply units (PSUs) are as follows:

Manufacturer Model Wattage Voltage (AC) Current (A) Frequency (Hz) Inlet/Outlet Efficiency
Supermicro PWS-2K08A-1R 1800 200-220 10-9.8 60/50 C14/C13 80 Plus Titanium (> 96%)
1980 220-230 10-9.8 60/50
2000 230-240 10-9.8 60/50
Supermicro PWS-3K02G-2R 2880 200-207 16-15.7 60/50 C20/C19 80 Plus Titanium (> 96%)
3000 207.1-240 16-14.5 60/50

Power connector inlets and outlets

This is what C14 inlets and C13 outlets look like:

This is what C20 inlets and C19 outlets look like:

2 - What regions do you do business in?

We do business directly in:

  • United States of America
  • Canada
  • Chile
  • European Union
  • Switzerland
  • United Kingdom
  • Iceland
  • United Arab Emirates
  • Saudi Arabia
  • South Africa
  • Israel
  • Taiwan
  • South Korea
  • Japan
  • Singapore
  • Australia
  • New Zealand

3 - Where can I download the user manual for my server chassis?

User manuals for Lambda server chassis can be downloaded below.

Supermicro

Chassis User manual
SuperServer 420GP-TNR Download
AS -4124GO-NART Download
AS -1124US-TNRP Download
AS -1114CS-TNR Download
AS -2124GQ-NART Download
AS -4023S-TRT Download
SuperServer 4029GP-TRT2 Download
SuperWorkstation 740GP-TNRT Download
AS -2124US-TNRP Download
SuperServer 420GP-TNAR Download

GIGABYTE

Chassis User manual
R152-Z33 Download
G292-Z43 Download
G292-Z24 Download
G292-Z22 Download
G292-Z42 Download
G292-280 Download

4 - Where can I find my server's IPMI (BMC) password?

Supermicro

On Supermicro chassis, the IPMI password appears on one or more of the following:

  • a sticker near the BMC (Baseboard Management Controller)

  • a sticker near the motherboard serial number label

  • the service tag

See Supermicro’s BMC Unique Password Guide [PDF] for more information.

GIGABYTE

On GIGABYTE chassis, the IPMI password appears on one or more of the following:

  • a sticker affixed to the motherboard

  • the chassis itself

See GIGABYTE’s BMC Unique Pre-Programmed Password Reference Guide [PDF] for more information.